2 resultados para Environmental Chemistry

em Brock University, Canada


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In light of the fact that literature on toxicity of heavy metals in non-acidified freshwater systems is sparse, this project was initiated to conduct an environmental assessment of Lake Gibson. Chemistry of soils from adjacent areas and vineyards in the region provide a comparative background database. Water quality determinations were used to identify and highlight areas of environmental concern within the Lake Gibson watershed. A Shelby Corer was used to obtain 66 sediment cores from Lake Gibson. These were sectioned according to lithology and color to yield 298 samples. A suite of 122 soil samples was collected in the region and vicinity of Lake Gibson. All were tested for metals and some for Total Petroleum Hydrocarbons (TPH). Evaluation of the results leads to the following conclusions: 1. Metal concentrations ofAI, Cd, Cu, Cr, Pb, Ni, Fe and Zn in soils from the Niagara Region are well below background limits set by the Ministry of the Environment and Energy (MOEE) for provincial soils. 2. There is a spatial and depth difference for some of the metals within the various soils. The Cr, Ni and Pb contents of soils vary throughout the region (penvironmental concern in the sediments of Lake Gibson. Ofthe 240 samples tested for TPH, 200 samples exceed the MOEE Open Water Disposal Guideline of 1,500 mg/kg. 7. Four areas within Lake Gibson are especially degraded with respect to TPH. One area is just downstream from the Old WeIland Canal divergence point and waterfall. Other areas of concern are located just south of Beaverdams Road and just west ofthe Ontario Hydro control pipes; south ofthe Village ofBeaverdams. The fourth area of environmental concern and TPH impact is located between Highway 406 and Merrittville Highway.